Journal of Guangdong University of Technology ›› 2006, Vol. 23 ›› Issue (1): 64-66.

• Comprehensive Studies • Previous Articles     Next Articles

Study on the Catalytical Spectrophotometric Determination of Trace Cobalt(Ⅱ) with Co(Ⅱ)-H2O2-Arsenazo M

  

  1. (Faculty of Chemical Engineering and Light Industry,Guangdong University of Technology,Guangzhou 510090,China)
  • Online:2006-02-02 Published:2006-02-02

Abstract: In the medium of dilute H2SO4,the fading reaction of Arsenazo M oxidized by H2O2,which can be catalyzed by Co(Ⅱ),has been studied.A new method for the catalytic spectrophotometric determination of trace cobalt has been developed.The lineer range is 0~0.08 mg/L and the detection limit is 1.73×10-9 g/L.The proposed method has been used to determine trace cobalt in vilamin B12 with satisfactory results.

Key words: cobalt; hydrogen peroxide; Arsenazo M; catalytic spectrophotomerty;

[1] 刘利平,张强,高建萍.  2,4-二氯苯基荧光酮催化分光光度法测定痕量钴[J]. 广东微量元素科学. 2001(08)

[2] 何纯莲,任凤莲,陈蓉.  过氧化氢氧化溴邻苯三酚红催化光度法测定痕量钴[J]. 光谱实验室. 2002(05)

[3] 李晓湘,唐冬秀,宋和付.  催化光度法测定煤矸石中微量钴[J]. 理化检验(化学分册). 2002(08)

[1] 鄢国强 编.工厂实用化学分析手册[M]. 机械工业出版社, 1995
No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!