广东工业大学学报 ›› 2017, Vol. 34 ›› Issue (06): 78-82.doi: 10.12052/gdutxb.160095

• 综合研究 • 上一篇    下一篇

利用平行光管检验校正台校正全站仪的竖盘指标差及2C

崔家武, 周波阳, 李锦城   

  1. 广东工业大学 土木与交通工程学院, 广东 广州 510006
  • 收稿日期:2016-07-30 出版日期:2017-11-09 发布日期:2017-11-22
  • 通信作者: 周波阳(1983-),男,助理研究员,博士,主要研究方向为航空重力测量数据处理.E-mail:wdzbyang@163.com E-mail:wdzbyang@163.com
  • 作者简介:崔家武(1992-),男,硕士研究生,主要研究方向为GNSS数据处理.
  • 基金资助:
    国家自然科学基金资助项目(41504013);武汉大学地球空间环境与大地测量教育部重点实验室测绘基础研究基金资助项目(14-01-03);广东工业大学博士启动基金资助项目(15ZK0008)

Calibrating the Index Error of Vertical Circle and 2C of Total Station Using a Calibrator Stand with Collimators

Cui Jia-wu, Zhou Bo-yang, Li Jin-cheng   

  1. School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
  • Received:2016-07-30 Online:2017-11-09 Published:2017-11-22

摘要: 竖盘指标差及2C值(两倍的视准轴误差)是影响全站仪角度测量精度的两个重要因素. 利用平行光管检验校正台分别对一台竖盘指标差超标的南方测绘NTS-312L型全站仪和一台2C超标的南方测绘NTS-312L型全站仪进行了校正. 校正后,前者的竖盘指标差从24"减小至6",后者的2C从19"减小至-6",校正结果符合《全站型电子速测仪检定规程JJG100-2003》. 为了对校正结果进行进一步检核,分别对两台全站仪进行了外业测试,结果显示,前者的竖盘指标差在-3"到6"范围内,后者的2C值在-6"到5"范围内,与实验结果基本符合.

关键词: 平行光管检验校正台, 全站仪, 竖盘指标差, 视准轴误差

Abstract: Index error of vertical circle and 2C value (two times of collimation axis error) are two important indicators which affect the precision of total station's angle measurement. A South NTS-312L total station with index error of vertical circle overrun and a South NTS-312L total station with 2C overrun are corrected by the calibrator stand with collimators. The experiments show that the index error of vertical circle of the former is reduced from 24" to 6" and 2C of the latter from 19" to -6" respectively after calibrating, the calibrating results according with Verification Regulation of Electronic Tachometer Total Station JJG100-2003. In order to check the calibration results further, both total stations are tested in a field survey, and the results show that the vertical index of the former changes between -3" to 6" range, and 2C value of the latter varies in -6" to 5" range, these numbers basically in agreement with the calibration experiment.

Key words: calibrator stand with collimators, total station, index error of vertical circle, collimation axis error

中图分类号: 

  • P202
[1] 周波阳,李锦城,黎家州,黄瑞龙. 采用平行光管检验校正台校正光学水准仪的 i[J]. 广东工业大学学报, 2016, 33(02): 15-18.