广东工业大学学报 ›› 2018, Vol. 35 ›› Issue (04): 61-67.doi: 10.12052/gdutxb.170099
陶浩文, 张孝春, 罗路娜, 冯锦华, 吴震岳
Tao Hao-wen, Zhang Xiao-chun, Luo Lu-na, Feng Jing-hua, Wu Zhen-yue
摘要: 以广州地铁3号线沥滘地铁站为例,通过火灾动力学数值模拟软件FDS (Fire Dynamics Simulator)研究了多火源情况下,空气幕厚度、空气射流速度及角度对火灾烟气阻挡效果的影响.通过对比数值模拟得到的烟气蔓延、温度变化与能见度变化情况,得到了楼梯口处设置挡烟空气幕时的特征参数适宜范围.
中图分类号:
[1] 白伟丽, 陈健. 线型光纤感温火灾探测监控系统的研究与设计[J]. 广东工业大学学报, 2016, 33(6):44-48.BAI W L, CHEN J. Investigation and design of a linear optical fiber sensing and monitoring system[J]. Journal of Guangdong University of Technology, 2016, 33(6):44-48. [2] 尹冬梅, 鲍鸿, 万频,等. 智能消防与保安系统设计[J]. 广东工业大学学报, 2006, 23(4):37-40.YIN D M, BAO H, WAN P, et al. Design of an intelligent fire prevention and security system[J]. Journal of Guangdong University of Technology, 2006, 23(4):37-40. [3] 黄骏. 浅析地铁站域公共空间的集约化发展[J]. 广东工业大学学报, 2007, 24(4):109-112.HUANG J. Discussion of the intensive development of public space at metro stations[J]. Journal of Guangdong University of Technology, 2007, 24(4):109-112. [4] 房营光, 方引晴. 城市地下工程安全性问题分析及病害防治方法[J]. 广东工业大学学报, 2001, 18(3):1-5.FANG Y G, FANG Y Q. Analysis of security and method of disaster prevention of underground engineering in city[J]. Journal of Guangdong University of Technology, 2001, 18(3):1-5. [5] 梁锐, 朱火保. 火灾时公共建筑中公众逃生行为分析及设计对策[J]. 广东工业大学学报, 2000, 17(1):37-42.LIANG R, ZHU H B. Escape behavior from fire in public building and design strategy[J]. Journal of Guangdong University of Technology, 2000, 17(1):37-42. [6] 中华人民共和国住房和城乡建设部. GB50157-201, 地铁设计规范[S]. 北京:中国建筑工业出版社, 2014. [7] 吴振坤.地铁车站敞开楼梯空气幕防火防烟分隔技术研究[D].合肥:中国科学技术大学安全科学与工程系,2015. [8] 黄仁武.地铁车站空气幕挡烟的应用研究[D].重庆:重庆大学资源及环境科学学院,2016. [9] 周吉伟.建筑火灾中空气幕挡烟的有效性研究[D].合肥:中国科学技术大学安全科学与工程系,2007. [10] 陈静,袁建平,方正. 地铁车站防烟空气幕阻烟效果模拟研究[J]. 消防科学与技术, 2015, 34(11):1431-1435.CHEN J, YUAN J P, FANG Z. Simulation study on the effect of blocking smoke for smoke air curtain in subway station[J]. Fire Science and Technology, 2015, 34(11):1431-1435. [11] 黄冬梅,梅秀娟,兰彬, 等. 出口风速对防烟空气幕防烟效果影响的数值模拟[J]. 中国安全生产科学技术, 2008, 4(2):31-34.HUANG D M, MEI X J, LAN B, et al. Numerical simulation on the influence to the effectiveness of smoke-preventing air curtain by the air outlet velocity[J]. Journal of Safety Science and Technology, 2008, 4(2):31-34. [12] GUYONNAUD L, SOLLIEC C. Design of air curtains used for area confinement in tunnels[J]. Experiments in Fluids, 2000, 28(4):377-384. [13] OLESZKIEWICZI. Fire exposure to exterior walls and flame spread on combustible cladding[J]. Fire Technology, 1990, 26(4):357-375. [14] 于群,刘畅,张亮. 浅析FDS火灾模拟与应用[J]. 水利与建筑工程学报, 2008, 6(4):124-126.YU Q, LIU C, ZHANG L. Analysis of FDS fire simulation and application[J]. Journal of Water conservancy and Architectural Engineering, 2008, 6(4):124-126. [15] 魏雨.地铁火灾人员安全疏散研究[D].沈阳:沈阳航空航天大学安全工程学院,2011. [16] 赵峰, 桂幸民. 低雷诺数效应对某可控扩散叶型性能的影响[J]. 航空动力学报, 2006, 21(2):285-289.ZHAO F, GUI X M. Influence of low reynolds number effect on the performance of a controlled diffusion[J]. Journal of Aerospace Power, 2006, 21(2):285-289. [17] 赵兰英.地铁火灾烟气的数值模拟及安全疏散对策研究[D].沈阳:沈阳建筑大学土木工程学院,2012. [18] 纪杰. 地铁站火灾烟气流动及通风控制模式研究[D]. 合肥:中国科学技术大学安全科学与工程系, 2008. [19] 全国冷冻设备标准化技术委员会. JB/T 9067-199, 空气幕[S]. 北京:机械工业部机械标准化研究, 1999. [20] 张贵宏,王延福. 空气幕的应用、现状和发展[J]. 企业科技与发展, 2012,(15):81-82.ZHANG G H, WANG Y F. The application status and development of air curtain[J]. Enterprise Science and Development, 2012,(15):81-82. [21] ALPERT R L. Calculation of response time of ceiling-mounted fire detectors[J]. Fire Technology, 1972, 8(3):181-195. |
[1] | 甘阳阳, 李志生. 空气幕对厨房内PM2.5控制效果的模拟与分析[J]. 广东工业大学学报, 2020, 37(03): 82-87. |
|