摘要: 提出一种新型医用高精密恒流电刺激器系统的整体方案,可作为诱发电位的电刺激器,也可用作功能式神经肌肉电刺激器。针对高精密恒流电刺激器对刺激电压高伏值和刺激电流高精确度的设计要求,电源设计部分采用推挽升压后再倍压整流得到一个平稳的360 V高压,同时电路中的12 bit D/A和运放组成的恒流源电路可以保证一个高质量的脉宽低于10 μs、最大100 mA恒定电流的产生。针对高精密恒流电刺激器的高人体安全系数的要求,对电路中的控制信号、反馈信号和通信信号采用光电隔离,并对供电电源采用DC-DC电源隔离屏蔽;同时设计了过流保护电路、脉宽限制电路和脉宽检错电路,结合底层硬件保护和上层脉宽检错电路的双重安全保护措施,大大提高了刺激器的安全系数。系统硬件电路的仿真和实际测试结果证明该设计方案的可行性和可靠性可满足临床医疗检测的要求。
中图分类号:
[1] DING J, WEXLER A S, BINDER-MACLEOD S A. Apredictive fatigue model part I: predicting the effect of stimulation frequency and patternon fatigue [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2002, 10(1): 48-58. [2] VERAART C, GRILL W M, MORTIMER J T. Selective control of muscl activation with a multipolar nerve cuff electrode [J]. IEEE Transactions on Biomedical Engineering, 1993, 40(1): 640-645. [3] NATHAN R, TAVI M. The influence of stimulation pulse frequency on the generation of joint moments in the upper limb [J]. IEEE Transactions on Biomedical Engineering, 1990, 37(3): 317-321. [4] LADENBAUER J, MINASSIAN K, HOFSTOETTER U S, et al. Stimulation of the human lumbar spinal cord with implanted and surface electrodes: a computer simulation study [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2010, 8(6): 637-645. [5] HUANG H, HE J P, HERMAN R, et al. Modulation effects of epidural spinal cord stimulationon muscle activities during walking [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2006, 14(1): 14-22. [6] GRAUPE D, KORDYLEWSKI H. Artificial neural network control of FES in paraplegics for patient responsive ambulation [J]. IEEE Transactions on Biomedical Engineering, 1995, 42(7): 699-707. [7] GEORGIOU J, TOUMAZOU C. A 126 μW Cochlear chip for a totally implantable system [J]. IEEE Journal Solid-State Circuits, 2005, 40(2): 430-443. [8] BHATTI P, WISE K. A 32-site 4-channel high-density electrode array for a Cochlear prosthesis [J]. IEEE Journal of Solid-State Circuits, 2006, 41(12): 2965-2973. [9] THEOGARAJAN L S. A low-power fully implantable 15-channel retinal stimulator chip [J]. IEEE Journal of Solid-State Circuits, 2008, 43(10): 143-145. [10] NOORSAL E, SOOKSOOD K, XU H C, et al. A neural stimulator frontend with high-voltage compliance and programmable pulse shape for epiretinal implants [J]. IEEE Journal of Solid-State Circuits, 2012, 47(1): 244-256. [11] TOKUDA T, HIYAMA K, SAWAMURA S, et al. CMOS-based multichip networked flexible retinal stimulator designed for image-based retinal prosthesis [J]. IEEE Transactions on Electron Devices, 2009, 56(11): 2577-2585. [12] HART R L, BHADRA N, MONTAGUE F W, et al. Design and testing of an advanced implantable neuroprosthesis with myoelectric control [J]. IEEE Journal of Solid-State Circuits, 2011, 19(1): 45-53. [13] THURGOOD B K, WARREN D J, LEDBETTER N M, et al. A wireless integrated circuit for 100-channel charge-balanced neural stimulation [J]. IEEE Transaction on Biomedical Circuit and Systems, 2009, 3(6): 405-413. [14] LIU X, DEMOSTHENOUS A, DONALDSON N. An integrated stimulator with DC-isolation and fine current control for implanted nerve tripoles [J]. IEEE Journal of Solid-StateCircuits, 2011, 46(7): 1701-1714. [15] CHIANG B, FRIDMAN G Y, CHENKAI D, et al. A micropower low-noise neural recording front-end circuit for epileptic seizure detection [J]. IEEE Journal of Solid-State Circuits, 2011, 46(6): 1392-1405. [16] CHIANG B, FRIDMAN G Y, CHENKAI D, et al. Design and performance of a multichannel vestibular prosthesis that restores semicircular [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2011, 19(5): 45-53. [17] LANGLOIS P J, IOANNIS P. High-power integrated stimulator output stages with floating discharge over a wide voltage [J]. IEEE Transaction on Biomedical Circuit and Systems, 2010, 4(1): 39-48. [18] CHENG K W, LU Y, TONG K Y, et al. Development of a circuit for functional electrical stimulation [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2004, 12(1): 43-46. [19] BROSER P J, CHRISTOPH B. Hydraulic driven fast and precise nonmagnetic tactile stimulator for neurophysiological and MEG measurements [J]. IEEE Transactions on Biomedical Engineering, 2012, 59(10): 2852-2858. [20] 彭杰, 杜玉晓, 杨其宇, 等. 一种新型EEG视觉诱发电位闪光刺激器的设计[J]. 广东工业大学学报, 2010, 27(3): 60-63. PENG J, DU Y X, YANG Q Y, et al. Design of a new type of EEG visual evoked potential flash stimulator [J]. Journal of Guangdong University of Technology, 2010, 27(3): 60-63. [21] 杜玉晓, 唐镇尧, 周伟, 等. 诱发电位仪系统设计实现方案[J]. 机电工程技术, 2013, 42(6): 84-90. DU Y X, TANG Z Y, ZHOU W, et al. Design and implementation of evoked potential system [J]. Mechanical & Electrical Engineering Technology, 2013, 42(6): 84-90. |
No related articles found! |
|