广东工业大学学报 ›› 2012, Vol. 29 ›› Issue (2): 58-62.doi: 10.3969/j.issn.1007-7162.2012.02.011
摘要: 研究污秽潮湿状态下复合绝缘子表面电场特性可有效地提高复合绝缘子运行的可靠性.综合考虑了复合绝缘子的污秽层厚度以及均匀性,在Comsol Multiphysics软件环境中建立了110 kV线路复合绝缘子的二维电场仿真模型,采用有限元法计算了复合绝缘子在不同污湿状态下的电位和电场分布.研究结果表明,当复合绝缘子表面形成均匀水膜润湿污秽层后,对绝缘子电场分布的影响程度与污层电导率有关,当污层电导率增大到10-7 S后,复合绝缘子高压端附近伞群承受的电场强度明显增强;当复合绝缘子表面有水滴滴落时,水滴周围的电场急剧增强.
[1]刘泽洪. 复合绝缘子使用现状及其在特高压输电线路中的应用前景[J]. 电网技术,2006,30(12):1-7. Liu Ze-hong. Present Situation and Prospects of Applying Composite Insulators to UHF Transmission Lines in China [J]. Power System Technology, 2006, 30(12): 1-7. [2] 刘兆林.1966年末华东电网雾闪事故分析及对策[J].电网技术, 1997, 21(8):63-66. Liu Zhao-lin. Analysis of fog flashover faults in east China power system at the end of 1996 and its countermeasures[J]. Power System Technology,1997,21(8):63-66. [3] 高航. 2001年初河南电网发生污闪事故的原因与防范措施[J]. 电网技术,2001,10:76-79. Gao Hang. Cause and countermeasure of pollution flashover in HeNan electric power network at the beginning of 2001[J]. PowerSystemTeehnology, 2001,25(10):76-79.[4] 关志成,梁曦东,张仁豫,等. 硅橡胶合成绝缘子染污放电机理的研究[J]. 清华大学学报,1999,39(5):16-19. Guan Zhi-cheng, Liang Xidong, Zhang Renyu,et al. Flashover mechanism of silicone rubber composite insulators[J]. Jouranal of Tsinghua University,1999,39(5):16-19.[5] 司马文霞, 刘贞瑶, 蒋兴良, 等. 硅橡胶表面分离水珠的局部放电对表面特性的影响[J]. 中国电机工程学报,2005,25(6):113-118. Sima wen-xia, Liu Zhenyao, Jiang Xingliang,et al. Effects on surface performance of partical discharges due to discrete water droplets on the silicone rubber[J]. Proceedings of the CSEE,2005,25(6):113118.[6] 于永清. 丧失憎水性的直流复合绝缘子耐污特性[J]. 电网技术,2005, 30(12):12-15. Yu Yong-qing. DC Contamination Flashover Performance of Composite Insulators Lost Hydrophobicity[J]. Power System Technology, 2006,30(12):12-15.[7] 罗兵, 饶宏, 黎小林. 直流复合绝缘子不均匀污秽闪络特性研究[J]. 高电压技术. 2006,32(12):133-136. Luo Bing, Rao Hong, Li Xiaolin. Study on ununiform pollution flashover characteristic of DC composite insulator[J]. High Voltage Engineering,2006,32(12):133-136.[8] Asebjq S E,Morales O N. Low frequency complex fields in polluted insulators[J]. IEEE Transactions on Electrical Insulation,1982,17(3):262-268.[9] Xu Guo-xing, Mcgrath P. Electrical and thermal analysis of Polymer insulator under contaminated surface conditions [J]. IEEE DEI,1996,3(2):289-298.[10] 项阳, 郭洁, 温定筠. 污秽潮湿状态下有机复合绝缘子周围电场分布研究[J]. 南方电网技术, 2010, 4(supplement):36-40. Xiang Yang, Guo Jie, Wen Dingjun. Study on electric field around transmission line composite insulators under polluted and wet condition[J]. Southern Power System Technology,2010,4(supplement):3640.[11] 司马文霞, 邵进, 杨庆. 应用有限元法计算覆冰合成绝缘子电位分布[J]. 高电压技术, 2007, 33(4):21-25. Sima Wenxia, Shao Jin, Yang Qing. Calculation of Potential Distribution to 220 kV Icing Nonceramic Insulators by Finete Element Method[J]. High Voltage Engineering, 2007, 33(4):21-25.[12] 肖猛, 文曹, 司马文霞, 等. 硅橡胶表面的分离水珠放电与不明原因闪络[J]. 重庆大学学报, 2006, 29(6):42-46. Xiao Meng, Wen Cao, Sima Wenxia, et al. Discharges between discrete water drops on the silicone rubber srufaceand reason unkown flashover[J]. Journal ofChongqingUniversity, 2006, 29(6):42-46. |
No related articles found! |
|