Journal of Guangdong University of Technology ›› 2016, Vol. 33 ›› Issue (03): 26-31.doi: 10.3969/j.issn.1007-7162.2016.03.005
Previous Articles Next Articles
Lin Jie-hui, Pan Yong-xiong, Su Cheng-yue, Sun An-quan
Received:
Online:
Published:
Abstract:
In order to solve the problem of BCM (boundary conduction mode) of single stage APFC (active power factor correction) flyback converter PF (power factor) that is not stable or even declines seriously under full voltage and variable load, a feedback compensation network is proposed to effectively stabilize PF, based on the analysis of the loop of voltage-mode BCM single-stage APFC flyback converter. Through a 30W voltage-mode BCM single-stage APFC flyback converter experimental prototype. The experimental results verify the validity of the feedback compensation network designed.
Key words: loop design; full voltage; variable load; boundary conduction mode(BCM); active power factor correction(APFC); flyback
LIN Jie-Hui, PAN Yong-Xiong, SU Cheng-Yue, SUN An-Quan. Loop Design of High PF BCM Single-stage APFC Flyback Converter under Full Voltage and Variable Load[J].Journal of Guangdong University of Technology, 2016, 33(03): 26-31.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://xbzrb.gdut.edu.cn/EN/10.3969/j.issn.1007-7162.2016.03.005